Seaton Burn tributary downstream of Industrial Estate
EA name: SEATON BURN TRIB D/S INDUSTRIAL ESTATE (also listed as “SEATON BURN TRIB AT RAILWAY CULVERT D/S SEAHAM GRANGE INDUSTRIAL ESTATE”)
Environment Agency sampling point NE-43505107 · Freshwater - rivers · listed as open (“open” does not mean it is sampled now)
These are samples taken on a date, not live readings of the river. Results reach the Environment Agency's archive days to months after the sample is taken, so the newest here may be weeks or months old. FloodRadar does not grade them.
Where and when
- Last sampled
- 22 Sep 2026, 12:269 days ago · time as the Environment Agency records it (UK clock time; the source gives no time zone)
- Samples banked
- 40 since 9 May 2025 Imported periods: 1 Oct 2023 – 30 Sep 2026. Samples outside them are not shown here.
- Latest sample
- River / running surface water Planned investigation (local monitoring) · results completed 25 Sep 2026
- Where
- National Grid 441334, 550441As published, to the nearest 1 m. Open in a map
- River, by its own name
- tributary of Seaton Burn
- River, by the map
- Seaton BurnOn an unmapped tributary: placed where it joins the river its name gives, 69 m from the line.
- Next gauge downstream
- None tracedThe map stops before any gauge.
- Why it was sampled
- Planned investigation (local monitoring) (40 samples)
Results here were completed a median of 2 days after the sample was taken (2 to 34 days, 24 samples). 32 visits found no water to sample (recorded as “No flow”).
Main measurements, river water
E. coli
confirmed, membrane filtration · code 2348 · per 100 ml
96000 per 100 ml
Sampled 19 Aug 2026, 43 days ago · 7 results banked
Every result (7)
| Sampled | Result as published | Reads as |
|---|---|---|
| 19 Aug 2026, 12:50 | 96000 | 96000 per 100 ml |
| 28 May 2026, 14:20 | 110000 | 110000 per 100 ml |
| 15 May 2026, 12:45 | 400 | 400 per 100 ml |
| 15 Sep 2025, 11:55 | 30000 | 30000 per 100 ml |
| 12 Aug 2025, 12:20 | 19000 | 19000 per 100 ml |
| 11 Jun 2025, 12:25 | 5000 | 5000 per 100 ml |
| 29 May 2025, 11:30 | 19000 | 19000 per 100 ml |
Everything measured here
6 determinands, each kept by its code, unit and sample material: results in different units or on different materials are never mixed. A “below” result is under the laboratory's detection limit, not zero.
Show all 6 rows
| Determinand | Material | Results | First – last | Latest result |
|---|---|---|---|---|
| Escherichia coli : Confirmed : MF 2348 | River water | 7 | May 2025 – Aug 2026 | 96000 per 100 ml 19 Aug 2026 |
| Enterococci: Intestinal: Confirmed: MF 3723 | River water | 7 | May 2025 – Aug 2026 | 130000 colony forming units / 100ml 19 Aug 2026 |
| Enterococci: Intestinal: Presumptive: MF 3722 | River water | 7 | May 2025 – Aug 2026 | 130000 colony forming units / 100ml 19 Aug 2026 |
| MST Filtration 4926 | River water | 8 | May 2025 – Aug 2026 | DNA Stored 19 Aug 2026 |
| No flow /No sample 7668 | River water | 32 | May 2025 – Sep 2026 | No flow/discharge at sampling point 22 Sep 2026 |
| Volume of Sample Filtered 4865 | River water | 8 | May 2025 – Aug 2026 | 310 millilitre 19 Aug 2026 |
FloodRadar does not grade these results: there is no overall score, and official river classifications are a separate dataset. A sample taken downstream of an overflow does not by itself show where anything in it came from. River connections and distances are traced on OS Open Rivers (edition 2026-04), which leaves out many small channels.
Water samples: Environment Agency Water Quality Archive, © Environment Agency and/or database right 2026, Open Government Licence v3.0.